Solid media · Technical article and analysis

3. Strain, stress and heat transfer during loading and release

Inspect the first and second mechanical periods, including the stress–strain response, heat-flow reversals and signed T–Q trajectories.

First period · Imposed strain and material response

The actuator imposes a straight strain ramp from 0 to −1,000 µε over 5 s, then returns to zero over the next 5 s. Stress is calculated from the evolving temperature and imposed strain. Heat initially leaves the warming solid, and continues to do so until 5.9324 s, after release has begun.

0.000 s · ε 0 µε · σ 0.0 kPa · solid 300.000 K · reservoir 300.000 K · heat into solid 0.0 W

Imposed engineering strain · Strain (µε)
-1,080-790-500-2108002.557.510Time (s)
Actuator command
Temperatures · Temperature (K)
297.469301.019304.569308.118311.66802.557.510Controlled release startsHeat flow reversesTime (s)
SolidFinite reservoir
Signed heat flow · Power (W)
-142.909-73.0092-3.1089266.7913136.69202.557.510Controlled release startsHeat flow reversesTime (s)
Positive into solid
Stress response · Stress (kPa)
-113,834-83,059.2-52,284.4-21,509.59,265.3102.557.510Time (s)
Calculated axial stress
Stress–strain trajectory · Stress (kPa)
-113,834-83,059.2-52,284.4-21,509.59,265.31-1,000-750-500-2500Engineering strain (µε)
Compression then release
Stress deviation from the first compression chord · Stress deviation (kPa)
-407.426-24.6365358.153740.9421,123.73-1,000-750-500-2500Engineering strain (µε)
Period 1 compressionPeriod 1 release

Purple vertical markers indicate mechanical reversals. Orange markers indicate heat-flow reversals.

At 10 s the strain has returned to zero. The solid is at 298.449 K and the stress at zero strain has changed because the actuator holds the cooler solid at its original length. Subtracting the first compression chord magnifies the separation between the two stress–strain branches and preserves the net work integral over the return to the original strain.

Second period · Compression starts from a different state

Both temperatures carry through the 10 s boundary. The reservoir initially supplies heat to the cooler solid during the second compression. The second period has heat-flow reversals at 10.9162 s and 15.9151 s. The two stress-deviation traces use the same chord so their offset stays visible.

0.000 s · ε 0 µε · σ 0.0 kPa · solid 300.000 K · reservoir 300.000 K · heat into solid 0.0 W

Imposed engineering strain · Strain (µε)
-1,080-790-500-2108005101520Time (s)
Actuator command
Temperatures · Temperature (K)
297.469301.02304.572308.123311.67505101520Controlled release startsControlled release startsHeat flow reversesHeat flow reversesHeat flow reversesTime (s)
SolidFinite reservoir
Signed heat flow · Power (W)
-142.917-72.9883-3.0593566.8697136.79905101520Controlled release startsControlled release startsHeat flow reversesHeat flow reversesHeat flow reversesTime (s)
Positive into solid
Stress response · Stress (kPa)
-113,837-83,061.7-52,285.9-21,510.29,265.5605101520Time (s)
Calculated axial stress
Stress deviation from the first compression chord · Stress deviation (kPa)
-407.426-24.6365358.153740.9421,123.73-1,000-750-500-2500Engineering strain (µε)
Period 1 compressionPeriod 1 releasePeriod 2 compressionPeriod 2 release
Temperature versus signed cumulative heat · Temperature (K)
297.469301.02304.572308.123311.675-516.445-387.334-258.223-129.1110Net heat into solid (J)
SolidFinite reservoir

Purple vertical markers indicate mechanical reversals. Orange markers indicate heat-flow reversals.

The T–Q plot uses signed cumulative heat into the solid. Its horizontal direction reverses with the heat flow. At fixed deformation, the solid's slope magnitude is 30% smaller than the reservoir's because their capacities are 100 and 70 J/K. During deformation, the thermoelastic term also changes the solid temperature and therefore its plotted slope.

Energy balances per completed mechanical period
PeriodHeat absorbed by solid (J)Heat rejected by solid (J)Net work input (J)
1345.497510.85310.216
2395.531399.0138.125